Input
Input range: -40 Vdc to -75 Vdc
Efficiency: > 80% typical
Output
Main DC voltage: +12 V @ 70 A; DS850DC / +12 V @ 52.5 A; DS650DC
Stand-By: +3.3 Vsb @ 6A (5V @ 4A available)
Regulation: +12 Vdc; +5%/-5% , +3.3 Vsb; +5%/-5%
Operating temperature: 0 to 50°C, unimpeded airflow
Storage temperature: -40 °C to +85 °C
Humidity: 20 to 90% RH, non-condensing
Nominal Output Voltage Set Point: 12.0 Vdc; 3.3 Vsb
Set Point Tolerance: ± 0.2%; ± 1%
Total Regulation: ± 5%; ± 5%
Minimum Current: 0 A; 0 A
Maximum Current: 70 A; 6.0 A
Output Ripple P/P: 120 mV; 50 mV
Reverse airflow