For full functionality of this site it is necessary to enable JavaScript.
EMIN.CO.TH
0
Product image

Ainuo AN9651S(F) Electrical Safety Comprehensive tester (Built-in AC power supply (5KW), PC, ESRS softwave)

Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

1) AC Hipot test
Booster rated output capacity: 500VA(5000V/100mA)
Booster maximum short-circuit current: >200mA
Output waveform: Sine wave
Output voltage setting: 500~5000V ± 3%
Frequency setting: 50Hz/60Hz ±0.1%
Current upper-limit: 0.10~99.99mA
Current lower-limit: 0.00~10.00mA
Compensation current : 0.00~10.00mA
Time setting: 1~999s
2) Insulation Resistance test
Rated output capacity: 2VA(1000V/2mA)
Output voltage setting: DC 500Vor1000V
Resistance upper-limit range: 0.0~99.9 MΩ,100~2000MΩ
Resistance lower-limit range: 0.3~99.9 MΩ, 100~2000MΩ
Insulation resistance measurement: 0.0~99.9 MΩ, 100~2000 MΩ
3) Ground Bond Resistance test
Output current setting: 3~30A
Current frequency setting: Sine waveform 50Hz/60Hz
4) Leakage Current test
Current upper-limit range: 0.050~9.999mA
Current lower-limit: 0.000~5.000mA
Leakage current compensation setting: 0.000~1.000mA
Leakage current measurement: 0.050~9.999mA
Output voltage measurement: 60~280V
Dimension (WxHxD): 483x600x1355
Gross weight: 80 kg

Product Detail

Main features
* Comply with CCC,IEC EN,VED,BS,UL,JIS standard requiements.
* Latest international standard:500VA AC Hipot capacity(AC 5KV/100mA),short-circuit output current exceeds 200mA.Built-in optional leakage current test network MD card,meeting requirements of different industrial standards Maximum test current of Ground Bond resistance is up to 64A
*6 in 1:AC Hipot,Insulation Resistance,Ground Bond resistance,Leakage Current,Running Power,Low-Voltage Start.
Standby power consumption is optional for AN9651F(F)and AN9651S(F),minimum is low to 0.50w,accuracy is 0.2%
* Simple operation:LED backlit screen display.menu operation,Chiense/English langues,socket test fixture.
* Flexible configuration:Built in isolated transformer,AC frequency conversion power supply,frequency conversion power supply and industrial PC combiantion

* Satisfy lattest requirements:Follow the production line developing trends of comprehensive,fast,automation and information.Satisfy quality management,5s management and refid management requirements.

AC Hipot test

 

Booster rated output capacity

500VA5000V/100mA

 

Booster maximum short-circuit current

>200mA

 

Output waveform

Sine wave, <3%pure resistance5000V/1mA),<3%From empty load to full load

 
 

Output voltage setting

Range

5005000V

 

Resolution

5V

 

Accuracy

±3%×setting+10V

 

Frequency setting

Range

50Hz/60Hz

 

Accuracy

±0.1%×setting

 

Alarming limits setting

Current upper-limit

0.1099.99mA

 

Current lower-limit

0.0010.00mA

 

Compensation current setting

Range

0.0010.00mA, automatic testing, compensation can be set to ON/OFF

 

Time setting

Range

1999s

 

Ramp up time range

1100s

 

Accuracy

±0.1%×setting+1count

 

Breakdown current alarm

Range

0.1099.99mA

 

Accuracy

±3%×reading+3counts

 

Insulation Resistance test

 

Rated output capacity

2VA1000V/2mA

 

Output voltage regulation

<3%From no load to full load

 

Output voltage ripple

<1%

 

Output

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.