For full functionality of this site it is necessary to enable JavaScript.
EMIN.CO.TH
0
Product image

Ainuo AN9602X(F) Ainuo AN9602X(F) AC Hipot tester (5kV/100mA)

Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Rated Output: 500VA (AC: 5kV/100mA)
Output Voltage Set and Range: 0.2kV~5.00kV AC,100mA 10V/step
Output Frequency Range: 50Hz, 60Hz (optional)
Output Waveform: Sine waveform, pure resistance, above 200V, distortion <5%
Upper and Lower Limit Leakage Current Setting:
+ AC: Upper: 0.10~100.00mA
+ Lower: 0.10~100.00mA(0=disable), 0.01mA/step
Breakdown Current Measurement Range: 0.100~3.499mA/3.50~100.00mA±2.5%
Test Time Setting Range: 1.0~999.9S
Test Time Setting Range/Resolution: 1.0~999.9s (LLL=continues) 0.1s/step
Test wire compensation: 0~0.500mA, manual clear offset
Interface: RS232(RS485 optional), Remote control(PLC)
Dimension W×H×D(mm): 450×150×440

 

Product Detail

Main features
* Latest international standard:Comply with CCC,IEC,EN,VDE,BS,UL,JIS standard requirements.
* Voltage ramp up/down,satisfy latest industrial standard requirements
* Breakdown current upper/lower limit setting,intelligent judgment,sound and light alarm
* AC 50/60HZ output
* Over voltage,over current protection,manual test wires compensation
* VFD display,simple operation
* Remote,RS232/485 interface

* Satisfy low voltage distribution industry latest requirements

Spec.

Model

AN9602X(F)

AN9605X(F)

AN9632X(F)

AN9671X(F)

AC Hipot Test

Rated Output

500VA
AC: 5kV/100mA

100VA(AC: 5kV/20mA)

 

Output Voltage Set and Range

0.2kV5.00kV AC,100mA 10V/step

0.2kV5.00kV AC, 10V/step

 

Output Voltage Adjustable Rate

±(2.5% of setting+10V)

 

Output Voltage Resolution/Accuracy

10V, ±(2.5% of setting+10V)

 

Output Frequency Range

50Hz, 60Hz (Optional)

 

Output Waveform

Sine waveform, pure resistance, above 200V, distortion <5%

 

Upper and Lower Limit Leakage Current Setting

AC: Upper: 0.10100.00mA, Lower:0.10100.00mA(0=disable), 0.01mA/step

AC: Upper: 0.1020.00mA, Lower:0.1020.00mA(0=disable), 0.01mA/step

 

Breakdown Current Measurement Range

0.1003.499mA/3.50100.00mA

0.1003.499mA/3.5020.00mA

 

Breakdown Current Accuracy

±(2.5% of reading+5 counts)

 

Ramp-up Time Setting Range/Resolution

1.0999.9s (0=disable) 0.1s/step

 

Test Time Setting Range/Resolution

1.0999.9s (LLL=continues) 0.1s/step

 

Test wire compensation

00.500mA, manual clear offset

 

Insulation Resistance Test

Output Voltage Setting and Measurement Range

 

100V 1000V DC 5V/step

Output Voltage Resolution/Accuracy

 

1V , ±(3% of setting+5V)

DC Ripple Coefficient

 

≤5% (1kV DC, <1mA, resistance load)

Output Voltage Adjustable Rate

 

±(3% of setting+5V)

Test Time Setting Range

 

1.0999.9s 0.1s/step (LLL= continues)

Lower limit of Insulation Resistance

 

12000M

Upper limit of Insulation Resistance

 

12000M (0=off)

Insulation Resistance Range

 

12000M, auto shift level

Insulation Resistance Accuracy

 

5001000V: ±(3% of reading+8counts) 1200M;
±(8% of reading+8counts) 200
2000M
Below 500V: ±(5% of reading+8counts) 1
200M;
±(10% of reading+8counts) 200
2000M

Interface Function

RS232(RS485 optional), Remote control(PLC)

Dimension W×H×D(mm)

450×150×440

320×110×400

               

 

 

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts