Sensor specifications

Particulate Matter (PMo & PM25)

Range: 0.000 to 1.000 mg/m3

Sensor type: LPC

Minimum detection limit: 0.001 mg/m3

Accuracy of factory calibration: ± (0.002 mg/m3 + 15% of reading)

Resolution: 0.001 mg/m3

Response time: 5 seconds

Temperature: 0 to 40°C

Relative Humidity: 0 to 90%

Ozone (O3)

Range: 0 - 0.15 ppm

Sensor type: GSS

Minimum detection limit: 0.001 ppm

Accuracy of factory calibration: <± 0.005 ppm

Resolution: 0.001 ppm

Response time: 60 seconds

Temperature: 0 to 40°C

Relative Humidity: 10 to 90%

Carbon Monoxide (CO)

Range: 0 - 25 ppm

Sensor type: GSE

Minimum detection limit: 0.05 ppm

Accuracy of factory calibration: <± 0.5 ppm 0-5 ppm; <± 10% 5-25 ppm

Resolution: 0.01 ppm

Response time: 60 seconds

Temperature: 0 to 40°C

Relative Humidity: 15 to 90%

Monitor specifications

Measurement units: Gas: ppm or mg/m3 | Humidity: % | Temperature °C or °F

Reading functions: Instant, minimum, maximum, average

Sensor head: Active fan sampling to ensure high accuracy measurements, interchangeable, replaceable

Sensor calibration: Zero and gain calibration in the lab or field

Analog output: 0 - 5 V

Digital logging: RS-232 to USB

Data logging: Up to 8,188 records (2,706 incl, Temp/RH)

PC data logging: Software and data cable supplied. Link data to a specific location and monitor.

Clock function: Real time

Power supply: 12V DC ( power adaptor/charge supplied 100-250 V AC)

Rechargeable battery: Lithium polymer 12 V DC 2700 mA/h

Enclosure material and rating: PC and ABS: IP20 and NEMA 1 equivalent

Size: (LxWxD) 195 x 122 x 54 (mm); 7⅝ x 4¾ x 2⅛ (in) (with sensor head)

Weight: < 460 g; < 16 oz (with sensor head and battery)

Environmental operation conditions: Temperature: -5°C to 45°C| Humidity: 0 to 95 % non-condensing

Temperature & Humidity sensor: Range -40°C to 124°C ( -40°F to 255°F); Range: 0 to 100% RH

Approvals: Part 15 of FCC Rules; EN 50082-1: 1997: EN 50081-1: 1992